Shop Medical Lab Equipment
Human NT-proBNP (N-Terminal Pro-Brain Natriuretic Peptide) ELISA Kit, 96 Tests, E-EL-H6126-96T
Elabscience® Human NT-proBNP(N-Terminal Pro-Brain Natriuretic Peptide) ELISA Kit, E-EL-H6126-96T
Product Summary
Sensitivity | 0.09 ng/mL |
Detection Range | 0.16-10 ng/mL |
Sample Volume | 100 μL |
Total Assay Time | 3 h 30 min |
Reacitivity | Human |
Specificity | This kit recognizes Human NT-proBNP in samples.No significant cross-reactivity or interference between Human NT-proBNP and analogues was observed |
Recovery | 80%-120% |
Sample Type | Serum, plasma and other biological fluids |
Detection Method | Colorimetric method, ELISA, Sandwich |
Assay Type | Sandwich-ELISA |
Size | 96T / 48T / 24T / 96T*5 / 96T*10 |
Storage | 2-8℃ |
Expiration Date | 12 months |
Test Principle
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human NT-proBNP. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NT-proBNP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NT-proBNP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Human NT-proBNP. You can calculate the concentration of Human NT-proBNP in the samples by comparing the OD of the samples to the standard curve.
Background
:
Uniport ID | P16860 |
Research Area | Cancer , Cardiovascular , Neuroscience |
- Serum Levels of Irisin Are Positively Associated with Improved Cardiac Function in Patients with Heart Failure with Reduced Ejection Fraction IF:3.9Journal: Biomedicines (2025) DOI:10.3390/biomedicines13040866 Reactivity: Human Sample Type: serum
- Irisin Predicts Poor Clinical Outcomes in Patients with Heart Failure with Preserved Ejection Fraction and Low Levels of N-Terminal Pro-B-Type Natriuretic Peptide IF:4.8Journal: Biomolecules (2024) DOI:10.3390/biom14121615 Reactivity: Human Sample Type: serum
- Trajectory of Irisin as a Predictor of Kidney-Related Outcomes in Patients with Asymptomatic Heart Failure IF:3.9Journal: Biomedicines (2024) DOI:10.3390/biomedicines12081827 Reactivity: Human Sample Type: serum
- Low Levels of Adropin Predict Adverse Clinical Outcomes in Outpatients with Newly Diagnosed Prediabetes after Acute Myocardial Infarction IF:3.9Journal: Biomedicines (2024) DOI:10.3390/biomedicines12081857 Reactivity: Human Sample Type: serum
- Predictors for Irreversibility of Contrast-Induced Acute Kidney Injury in Patients with Obesity After Contrast-Enhanced Computed Tomography Coronary Angiography IF:3.4Journal: ADVANCES IN THERAPY (2024) DOI:10.1007/s12325-024-03036-z Reactivity: Human Sample Type: serum
- Improving DNA Aptamers Against Heart Failure Protein Biomarker Using Structure-Guided Random Mutations Approaches for Colourimetric Biosensor Development IF:3.2Journal: Molecular Systems Design & Engineering (2024) DOI:10.1039/D4ME00073K Reactivity: Human Sample Type: plasma
- Adropin Predicts Asymptomatic Heart Failure in Patients with Type 2 Diabetes Mellitus Independent of the Levels of Natriuretic Peptides IF:3.0Journal: Diagnostics (2024) DOI:10.3390/diagnostics14161728 Reactivity: Human Sample Type: serum
- Evaluation of some nonroutine cardiac biomarkers among adults and children with beta-thalassemia major IF:1.3Journal: LABORATORY MEDICINE (2024) DOI:10.1093/labmed/lmae007 Reactivity: Human Sample Type: serum
- Retrospective study on the short-term efficacy of different doses of Spironolactone in patients with heart failure of ischemic cardiomyopath and the influence of ventricular remodeling markers IF:1.3Journal: American Journal of Cardiovascular Disease (2024) DOI:PMID:38495408 Reactivity: Human Sample Type: serum
- Predischarge Peak Atrial Longitudinal Strain and Plasma N-terminal Pro-hormone Brain Natriuretic Peptide as a Predictor of Short-term Rehospitalization and Cardiovascular Mortality in Patients with Acute Heart Failure IF:0.7Journal: Journal of Cardiovascular Echography (2024) DOI:10.4103/jcecho.jcecho_70_23 Reactivity: Human Sample Type: Blood sample
- Investigation of the efficacy of beta-blockers and reninangiotensin-aldosterone system inhibitors in chronic heart failure with preserved ejection fraction IF:0.6Journal: TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH (2024) DOI:10.4314/tjpr.v23i1.22 Reactivity: Human Sample Type: serum
- Circulating Cell-Free Nuclear DNA Predicted an Improvement of Systolic Left Ventricular Function in Individuals with Chronic Heart Failure with Reduced Ejection Fraction IF:0.5Journal: Cardiogenetics (2024) DOI:10.3390/cardiogenetics14040014 Reactivity: Human Sample Type: Serum
- Axin2 depletion in macrophages alleviated senescence and increased immune response after myocardial infarction IF:6.7Journal: INFLAMMATION RESEARCH (2023) DOI:10.1007/s00011-023-01843-8 Reactivity: Human Sample Type: epicardial tissue
- The Impact of SGLT2 Inhibitor Dapagliflozin on Adropin Serum Levels in Men and Women with Type 2 Diabetes Mellitus and Chronic Heart Failure IF:4.700Journal: Biomedicines (2023) DOI:10.3390/biomedicines11020457 Reactivity: Human Sample Type: serum
- Adropin Predicts Chronic Kidney Disease in Type 2 Diabetes Mellitus Patients with Chronic Heart Failure IF:3.900Journal: Journal of Clinical Medicine (2023) DOI:10.3390/jcm12062231 Reactivity: Human Sample Type: Serum
- Predictors of Kidney Function Outcomes and Their Relation to SGLT2 Inhibitor Dapagliflozin in Patients with Type 2 Diabetes Mellitus Who Had Chronic Heart Failure IF:3.8Journal: ADVANCES IN THERAPY (2023) DOI:10.1007/s12325-023-02683-y Reactivity: Human Sample Type: serum
- Low Plasma Levels of Irisin Predict Acutely Decompensated Heart Failure in Type 2 Diabetes Mellitus Patients with Chronic Heart Failure IF:2.400Journal: Journal of Cardiovascular Development and Disease (2023) DOI:10.3390/jcdd10040136 Reactivity: Human Sample Type: serum
- Total Antioxidant Capacity and Prediabetes Are Associated with Left Ventricular Geometry in Heart-Failure Patients with Reduced Ejection Fraction: A Cross-Sectional Study IF:2.1Journal: Metabolic Syndrome and Related Disorders (2023) DOI:10.1089/met.2023.0019 Reactivity: Human Sample Type: serum
- Effect of Metformin on Oxidative Stress and Left Ventricular Geometry in Nondiabetic Heart Failure Patients: A Randomized Controlled Trial IF:2.1Journal: Metabolic Syndrome and Related Disorders (2023) DOI:10.1089/met.2023.0164 Reactivity: Human Sample Type: left ventricular
- The effect of heart failure on gut microbial richness and diversity IF:1.800Journal: Revista Portuguesa de Cardiologia (2023) DOI:10.1016/j.repc.2022.06.016 Reactivity: Human Sample Type: serum
- Combined Use of Serum N-terminal Pro-B-Type Natriuretic Peptide and Glypican-6 in the Diagnosis of Heart Failure IF:1.2Journal: Cureus Journal of Medical Science (2023) DOI:10.7759/cureus.45766 Reactivity: Human Sample Type: serum
- Lower Circulating Cell-Free Mitochondrial DNA Is Associated with Heart Failure in Type 2 Diabetes Mellitus Patients IF:0.600Journal: Cardiogenetics (2023) DOI:10.3390/cardiogenetics13010003 Reactivity: Human Sample Type: blood
- Discriminative Value of Serum Irisin in Prediction of Heart Failure with Different Phenotypes among Patients with Type 2 Diabetes Mellitus IF:7.666Journal: Cells (2022) DOI:10.3390/cells11182794 Reactivity: Human Sample Type: plasma
- The Association of Glucose Control with Circulating Levels of Red Blood Cell-Derived Vesicles in Type 2 Diabetes Mellitus Patients with Atrial Fibrillation IF:6.208Journal: INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES (2022) DOI:10.3390/ijms24010729 Reactivity: Human Sample Type: serum
- The Effect of SGLT2 Inhibitor Dapagliflozin on Serum Levels of Apelin in T2DM Patients with Heart Failure IF:4.757Journal: Biomedicines (2022) DOI:10.3390/biomedicines10071751 Reactivity: Human Sample Type: serum
- Serum Levels of Irisin Predict Cumulative Clinical Outcomes in Heart Failure Patients With Type 2 Diabetes Mellitus IF:4.755Journal: Frontiers in Physiology (2022) DOI:10.3389/fphys.2022.922775 Reactivity: Human Sample Type: serum
- Discriminative Utility of Apelin-to-NT-Pro-Brain Natriuretic Peptide Ratio for Heart Failure with Preserved Ejection Fraction among Type 2 Diabetes Mellitus Patients IF:4.415Journal: Journal of Cardiovascular Development and Disease (2022) DOI:10.3390/jcdd9010023 Reactivity: Human Sample Type: plasma
- The Role of Circulating Collagen Turnover Biomarkers and Late Gadolinium Enhancement in Patients with Non-Ischemic Dilated Cardiomyopathy IF:3.992Journal: Diagnostics (2022) DOI:10.3390/diagnostics12061435 Reactivity: Human Sample Type: serum
- Interplay between Myokine Profile and Glycemic Control in Type 2 Diabetes Mellitus Patients with Heart Failure IF:3.992Journal: Diagnostics (2022) DOI:10.3390/diagnostics12122940 Reactivity: Human Sample Type: serum
- Predictive value of serum irisin for chronic heart failure in patients with type 2 diabetes mellitus Journal: Molecular Biomedicine (2022) DOI:10.1186/s43556-022-00096-x Reactivity: Human Sample Type: serum
- The comparison of endothelial function of moderate intensity interval exercise with continuous exercise in healthy men Journal: Current Research in Physiology (2022) DOI:10.1016/j.crphys.2022.07.003 Reactivity: Human Sample Type: serum
- Compound Danshen Dripping Pill inhibits doxorubicin or isoproterenol-induced cardiotoxicity IF:6.530Journal: BIOMEDICINE & PHARMACOTHERAPY (2021) DOI:10.1016/j.biopha.2021.111531 Reactivity: Human Sample Type: Cell culture supernatant
- Could VEGF-D level have a role in clinical risk scoring, estimation of thrombus burden, and treatment in acute pulmonary thromboembolism? IF:2.503Journal: INTERNATIONAL JOURNAL OF CLINICAL PRACTICE (2021) DOI:10.1111/ijcp.14601 Reactivity: Human Sample Type: blood
- The combined role of NT-proBNP and LV-GLS in the detection of early subtle chemotherapy-induced cardiotoxicity in breast cancer female patients Journal: Egyptian Heart Journal (2021) DOI:10.1186/s43044-021-00142-z Reactivity: Human Sample Type: blood
- Impact of lipophilic vs hydrophilic statins on the clinical outcome and biomarkers of remodelling in heart failure patients: A prospective comparative randomized study IF:3.740Journal: BRITISH JOURNAL OF CLINICAL PHARMACOLOGY (2020) DOI:10.1111/bcp.14695 Reactivity: Human Sample Type: serum
- Incremental Predictive Value of Longitudinal Axis Strain and Late Gadolinium Enhancement Using Standard CMR Imaging in Patients with Aortic Stenosis IF:5.688Journal: Journal of Clinical Medicine (2019) DOI:10.3390/jcm8020165 Reactivity: Human Sample Type: Serum
- Role of sympathetic cotransmitter galanin on autonomic balance in heart failure: an active player or a bystander? IF:1.190Journal: Anatolian Journal of Cardiology (2017) DOI:10.14744/AnatolJCardiol.2017.7831 Reactivity: Human Sample Type: Serum
Frequently Asked Questions
-
Why is IntelixBio LLC so popular?
IntelixBio has swiftly become a household name in the medical industry, primarily owing to its cutting-edge medical lab equipment. Our commitment to excellence resonates through every facet of our products, ensuring that laboratories worldwide receive top-tier solutions for their diagnostic needs. Our medical lab equipment is engineered with precision and innovation, embodying the pinnacle of technological advancement in the field. From state-of-the-art analyzers to automated specimen-handling systems, our extensive catalog caters to diverse laboratory requirements, fostering efficiency and accuracy in every diagnostic process. Laboratories entrust IntelixBio's medical lab equipment for its unwavering reliability, empowering healthcare professionals with the tools they need to deliver optimal patient care.
At IntelixBio, our dedication to advancing healthcare is exemplified through our unparalleled range of medical lab equipment. Each product is meticulously crafted to meet the exacting standards of modern laboratory environments, facilitating seamless integration and operation. Our commitment to quality permeates every aspect of our offerings, ensuring that laboratories can consistently rely on our medical lab equipment to deliver precise and dependable results. With a comprehensive selection that spans from basic laboratory essentials to sophisticated diagnostic instruments, IntelixBio remains the foremost choice for institutions seeking excellence in medical equipment solutions. Trust IntelixBio to elevate your laboratory capabilities with our innovative medical lab equipment, empowering you to drive progress in healthcare delivery.
-
What products do you offer?
At IntelixBio LLC, we offer high-quality medical lab equipment. Our lab supplies include:
- Protective gear
- Antibody immunodetection supplies
- Bioreagents
- Lab Supplies
- Immunohistochemistry Tools
- Instruments and Equipment
- PPE
- Sample preparation supplies
Visit our online shop to view our available medical lab equipment and purchase the items that match your unique styles and needs today.
-
Where do you ship your medical lab equipment?
We ship our medical lab equipment to customers nationwide. Browse our online shop to view our impressive inventory of available lab equipment today and purchase the products that meet your unique style and needs. We can't wait to prove why Intelixbio.com is one of the nation's best medical lab supply providers.
-
How can I contact your company?
You can reach IntelixBio LLC by phone at 240-316-3161, by email at info@intelixbio.com, or by filling out one of the contact forms on our website.
When you contact our team, you can expect fast, friendly, and professional assistance with all your medical lab equipment needs.